LINKS
LINKS
How to check the current setting by sending the command
Announcer: Stephen Time: 26th Jul 2021
Share to :
MORE
1209 views 0 comments


Send the following command to the device, then the device will replay as following:

Item

Query command(HEX)

Response

Sensitivity:

7E 00 00 05 33 44 30 32 30 BF

02 00 00 06 34 30 32 31 30 32 3F: High
02 00 00 06 34 30 32 31 31 34 3F: Low

Default scan mode:

7E 00 00 05 33 44 30 30 30 BD

02 00 00 04 34 30 30 30 F5: Trigger Mode
02 00 00 04 34 30 30 31 3F: Sense Mode
02 00 00 04 34 30 30 32 3F: Continuous Mode

Illumination:

7E 00 00 02 33 35 FB

02 00 00 05 34 00 00 00 00 3F: Normal
02 00 00 05 34 00 00 00 08 3F: Off
02 00 00 05 34 00 00 00 04 3F: Always on

Good Read LED :

7E 00 00 02 33 61 AF

02 00 00 06 34 31 30 35 30 30 3F: Enable
02 00 00 06 34 30 30 35 30 30 3F: Disable

 


All comments (0)
POPULAR TAGS